Skip to main content

Brocade FC Switch

Plugin: go.d.plugin Module: snmp

Overview

Monitor Brocade FC Switch (switch) with Netdata over SNMP. Netdata recognizes the device automatically by its sysObjectID (recognized across 16 device identifiers) and collects the metrics this profile declares — on top of the generic SNMP baseline — with no manual OID configuration.

Netdata's SNMP collector matches the device to the brocade-fc-switch.yaml profile via sysObjectID/sysDescr, then polls the OIDs it declares.

This integration is supported on all platforms.

This integration supports multiple instances configured side-by-side.

Default Behavior

Auto-Detection

Auto-detected as Brocade FC Switch via sysObjectID/sysDescr.

Limits

The default configuration for this integration does not impose any limits.

Performance Impact

The default configuration for this integration is not expected to impose a significant performance impact on the system.

Setup

You can configure the snmp collector in two ways:

MethodBest forHow to
UIFast setup without editing filesGo to Nodes → Configure this node → Collectors → Jobs, search for snmp, then click + to add a job.
FileIf you prefer configuring via file, or need to automate deployments (e.g., with Ansible)Edit go.d/snmp.conf and add a job.
important

UI configuration requires paid Netdata Cloud plan.

Prerequisites

SNMP access

SNMP must be enabled on the device and reachable from the Netdata Agent acting as the site's SNMP hub.

Configuration

Options

Configure the SNMP collector with the device hostname and SNMP credentials. See the SNMP collector reference for all options.

via UI

Configure the snmp collector from the Netdata web interface:

  1. Go to Nodes.
  2. Select the node where you want the snmp data-collection job to run and click the (Configure this node). That node will run the data collection.
  3. The Collectors → Jobs view opens by default.
  4. In the Search box, type snmp (or scroll the list) to locate the snmp collector.
  5. Click the + next to the snmp collector to add a new job.
  6. Fill in the job fields, then click Test to verify the configuration and Submit to save.
    • Test runs the job with the provided settings and shows whether data can be collected.
    • If it fails, an error message appears with details (for example, connection refused, timeout, or command execution errors), so you can adjust and retest.

via File

The configuration file name for this integration is go.d/snmp.conf.

The file format is YAML. Generally, the structure is:

update_every: 1
autodetection_retry: 0
jobs:
- name: some_name1
- name: some_name2

You can edit the configuration file using the edit-config script from the Netdata config directory.

cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/snmp.conf
Examples

There are no configuration examples.

Alerts

There are no alerts configured by default for this integration.

Metrics

On top of the generic SNMP baseline (the Generic SNMP Device integration — interfaces, system, IP/TCP/UDP, host resources), this Brocade FC Switch profile adds the metrics below. Each is collected only where the device exposes the matching OID — inclusion means the profile requests it; availability depends on the device model and software.

27 metrics in 5 groups; each row is a chart context usable in alerts.

GroupMetrics
Network / FibreChannel20
Network / Interface4
System / CPU1
System / Memory1
System / Uptime1

Network / FibreChannel

Metric (chart context)UnitScopeDescription
snmp.device_prof_fcFxPortAdminMode{status}per fc_fe_module_index, fc_fx_port_indexDesired operational mode of the FxPort
snmp.device_prof_fcFxPortBbCreditAvailable{buffer}per fc_fe_module_index, fc_fx_port_indexBuffers currently available for receiving frames from the attached port in the buffer-to-buffer flow control
snmp.device_prof_fcFxPortOperMode{status}per fc_fe_module_index, fc_fx_port_indexOperational mode of the FxPort
snmp.device_prof_fcFxPortPhysAdminStatus{status}per fc_fe_module_index, fc_fx_port_indexDesired state of the FxPort
snmp.device_prof_fcFxPortPhysOperStatus{status}per fc_fe_module_index, fc_fx_port_indexCurrent operational status of the FxPort
snmp.device_prof_swFCPortC3Discards{frame}/sper sw_fc_port_name, sw_fc_port_specifierNumber of Class 3 frames discarded by the port.
snmp.device_prof_swFCPortNoTxCredits{time}/sper sw_fc_port_name, sw_fc_port_specifierNumber of times when the transmit credit has reached zero
snmp.device_prof_swFCPortRcTruncs{frame}/sper sw_fc_port_name, sw_fc_port_specifierNumber of truncated frames received by the port
snmp.device_prof_swFCPortRxBadEofs{frame}/sper sw_fc_port_name, sw_fc_port_specifierNumber of received frames with bad EOF delimiter
snmp.device_prof_swFCPortRxBadOs{error}/sper sw_fc_port_name, sw_fc_port_specifierNumber of invalid Ordered Sets received
snmp.device_prof_swFCPortRxC2Frames{frame}/sper sw_fc_port_name, sw_fc_port_specifierNumber of Class 2 frames received by the port
snmp.device_prof_swFCPortRxC3Frames{frame}/sper sw_fc_port_name, sw_fc_port_specifierNumber of Class 3 frames received by the port
snmp.device_prof_swFCPortRxCrcs{error}/sper sw_fc_port_name, sw_fc_port_specifierNumber of CRC errors detected for frames received
snmp.device_prof_swFCPortRxEncInFrs{error}/sper sw_fc_port_name, sw_fc_port_specifierNumber of encoding or disparity errors inside frames received.
snmp.device_prof_swFCPortRxEncOutFrs{error}/sper sw_fc_port_name, sw_fc_port_specifierNumber of encoding or disparity errors outside frames received
snmp.device_prof_swFCPortRxFrames{frame}/sper sw_fc_port_name, sw_fc_port_specifierNumber of Fibre Channel frames received by the port
snmp.device_prof_swFCPortRxLCs{frame}/sper sw_fc_port_name, sw_fc_port_specifierNumber of Link Control frames received by the port
snmp.device_prof_swFCPortRxTooLongs{frame}/sper sw_fc_port_name, sw_fc_port_specifierNumber of received frames that are too long
snmp.device_prof_swFCPortTooManyRdys{time}/sper sw_fc_port_name, sw_fc_port_specifierNumber of times when RDYs exceeds the frames received
snmp.device_prof_swFCPortTxFrames{frame}/sper sw_fc_port_name, sw_fc_port_specifierNumber of Fibre Channel frames transmitted by the port

Network / Interface

Metric (chart context)UnitScopeDescription
snmp.device_prof_ifAdminStatus{status}per interface, interfaceCurrent administrative state of the interface
snmp.device_prof_ifHighSpeedbit/sper interface, interfaceEstimate of the interface's current bandwidth
snmp.device_prof_ifNumber{interface}deviceNumber of network interfaces regardless of their current state present on this system
snmp.device_prof_ifOperStatus{status}per interface, interfaceCurrent operational state of the interface

System / CPU

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpu_usage%deviceThe current CPU utilization

System / Memory

Metric (chart context)UnitScopeDescription
snmp.device_prof_memory_usage%deviceSystem's memory usage

System / Uptime

Metric (chart context)UnitScopeDescription
snmp.device_prof_systemUptimesdeviceTime since the system was last rebooted or powered on.

Do you have any feedback for this page? If so, you can open a new issue on our netdata/learn repository.