NEC Univerge

Plugin: go.d.plugin Module: snmp

Overview

Monitor NEC Univerge (network device) with Netdata over SNMP. Netdata recognizes the device automatically by its sysObjectID (recognized across 2 device identifiers) and collects the metrics this profile declares — on top of the generic SNMP baseline — with no manual OID configuration.

Netdata's SNMP collector matches the device to the nec-univerge.yaml profile via sysObjectID/sysDescr, then polls the OIDs it declares.

This integration is supported on all platforms.

This integration supports multiple instances configured side-by-side.

Default Behavior

Auto-Detection

Auto-detected as NEC Univerge via sysObjectID/sysDescr.

Limits

The default configuration for this integration does not impose any limits.

Performance Impact

The default configuration for this integration is not expected to impose a significant performance impact on the system.

Setup

You can configure the snmp collector in two ways:

MethodBest forHow to
UIFast setup without editing filesGo to Nodes → Configure this node → Collectors → Jobs, search for snmp, then click + to add a job.
FileIf you prefer configuring via file, or need to automate deployments (e.g., with Ansible)Edit go.d/snmp.conf and add a job.
important

UI configuration requires paid Netdata Cloud plan.

Prerequisites

SNMP access

SNMP must be enabled on the device and reachable from the Netdata Agent acting as the site's SNMP hub.

Configuration

Options

Configure the SNMP collector with the device hostname and SNMP credentials. See the SNMP collector reference for all options.

via UI

Configure the snmp collector from the Netdata web interface:

  1. Go to Nodes.
  2. Select the node where you want the snmp data-collection job to run and click the (Configure this node). That node will run the data collection.
  3. The Collectors → Jobs view opens by default.
  4. In the Search box, type snmp (or scroll the list) to locate the snmp collector.
  5. Click the + next to the snmp collector to add a new job.
  6. Fill in the job fields, then click Test to verify the configuration and Submit to save.
    • Test runs the job with the provided settings and shows whether data can be collected.
    • If it fails, an error message appears with details (for example, connection refused, timeout, or command execution errors), so you can adjust and retest.

via File

The configuration file name for this integration is go.d/snmp.conf.

The file format is YAML. Generally, the structure is:

update_every: 1
autodetection_retry: 0
jobs:
- name: some_name1
- name: some_name2

You can edit the configuration file using the edit-config script from the Netdata config directory.

cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/snmp.conf
Examples

There are no configuration examples.

Alerts

There are no alerts configured by default for this integration.

Metrics

On top of the generic SNMP baseline (the Generic SNMP Device integration — interfaces, system, IP/TCP/UDP, host resources), this NEC Univerge profile adds the metrics below. Each is collected only where the device exposes the matching OID — inclusion means the profile requests it; availability depends on the device model and software.

47 metrics in 7 groups; each row is a chart context usable in alerts.

GroupMetrics
Hardware / Sensor1
Hardware / Temperature2
Network / Interface4
Network / VPN37
System / CPU1
System / Memory1
System / Uptime1

Hardware / Sensor

Metric (chart context)UnitScopeDescription
snmp.device_prof_nec_picoVoltagemVdeviceIndicates the observed voltage

Hardware / Temperature

Metric (chart context)UnitScopeDescription
snmp.device_prof_nec_picoCelsiusCeldeviceIndicates the temperature of the equipment inside
snmp.device_prof_nec_picoFahrenheitdegFdeviceIndicates the temperature of the equipment inside

Network / Interface

Metric (chart context)UnitScopeDescription
snmp.device_prof_ifAdminStatus{status}per interface, interfaceCurrent administrative state of the interface
snmp.device_prof_ifHighSpeedbit/sper interface, interfaceEstimate of the interface's current bandwidth
snmp.device_prof_ifNumber{interface}deviceNumber of network interfaces regardless of their current state present on this system
snmp.device_prof_ifOperStatus{status}per interface, interfaceCurrent operational state of the interface

Network / VPN

Metric (chart context)UnitScopeDescription
snmp.device_prof_nec_pikeGlobalActiveTunnels{tunnel}deviceCurrently active IPsec Phase-1 IKE Tunnels
snmp.device_prof_nec_pikeGlobalAuthFails{failure}/sdeviceAuthentications which ended in failure by IPsec Phase-1 IKE Tunnels
snmp.device_prof_nec_pikeGlobalDecryptFails{failure}/sdeviceDecryptions which ended in failure by IPsec Phase-1 IKE Tunnels
snmp.device_prof_nec_pikeGlobalHashValidFails{failure}/sdeviceHash validations which ended in failure by IPsec Phase-1 Tunnels
snmp.device_prof_nec_pikeGlobalInNotifys{notification}/sdeviceNotifys received by IPsec Phase-1 IKE Tunnels
snmp.device_prof_nec_pikeGlobalInP1SaDelRequests{request}/sdeviceISAKMP security association delete requests received by IPsec Phase-1 Tunnels
snmp.device_prof_nec_pikeGlobalInP2ExchgInvalids{exchange}/sdeviceIPsec Phase-2 exchanges which were received and found to be contain references to unrecognized security parameters
snmp.device_prof_nec_pikeGlobalInP2ExchgRejects{exchange}/sdeviceIPsec Phase-2 exchanges which were received and validated but were rejected by the local policy
snmp.device_prof_nec_pikeGlobalInP2Exchgs{exchange}/sdeviceIPsec Phase-2 exchanges received by IPsec Phase-1 IKE Tunnels
snmp.device_prof_nec_pikeGlobalInP2SaDelRequests{request}/sdeviceIPsec Phase-2 security association delete requests received by IPsec Phase-1 IKE Tunnels
snmp.device_prof_nec_pikeGlobalInitTunnelFails{tunnel}/sdeviceIPsec Phase-1 IKE Tunnels which were locally initiated and failed to activate
snmp.device_prof_nec_pikeGlobalInitTunnels{tunnel}deviceIPSec Phase-1 IKE Tunnels which were locally initiated
snmp.device_prof_nec_pikeGlobalOutNotifys{notification}/sdeviceNotifys sent by IPsec Phase-1 IKE Tunnels
snmp.device_prof_nec_pikeGlobalOutP1SaDelRequests{request}/sdeviceISAKMP security association delete requests sent by IPsec Phase-1 Tunnels
snmp.device_prof_nec_pikeGlobalOutP2ExchgInvalids{exchange}/sdeviceIPsec Phase-2 exchanges which were sent and were flagged by the peer to contain references to unrecognized security parameters
snmp.device_prof_nec_pikeGlobalOutP2ExchgRejects{exchange}/sdeviceIPsec Phase-2 exchanges which were sent, validated by the peer but were rejected by the peers policy
snmp.device_prof_nec_pikeGlobalOutP2Exchgs{exchange}/sdeviceIPsec Phase-2 exchanges which were sent by IPsec Phase-1 IKE Tunnels
snmp.device_prof_nec_pikeGlobalOutP2SaDelRequests{request}/sdeviceIPsec Phase-2 SA delete requests sent by IPsec Phase-1 IKE Tunnels
snmp.device_prof_nec_pikeGlobalRespTunnelFails{tunnel}/sdeviceIPsec Phase-1 IKE Tunnels which were remotely initiated and failed to activate
snmp.device_prof_nec_pikeGlobalRespTunnels{tunnel}/sdeviceIPsec Phase-1 IKE Tunnels hich were remotely initiated
snmp.device_prof_nec_pipSecGlobalActiveTunnels{tunnel}deviceCurrently active IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalInAuthFails{failure}/sdeviceInbound authentication which ended in failure by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalInAuths{authentication}/sdeviceInbound authentications performed by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalInDecryptFails{failure}/sdeviceInbound decryptions which ended in failure by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalInDecrypts{decryption}/sdeviceInbound decryptions performed by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalInDrops{packet}/sdevicePackets dropped during receive processing by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalInOctetsBy/sdeviceData received by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalInPkts{packet}/sdevicePackets received by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalInReplayDrops{packet}/sdevicePackets dropped during receive processing due to Anti-Replay processing by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalNoSaFails{failure}/sdeviceNon-existent SA in failures which occurred during processing by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalOutAuthFails{failure}/sdeviceOutbound authentication's which ended in failure by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalOutAuths{authentication}/sdeviceOutbound authentications performed by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalOutDrops{packet}/sdevicePackets dropped during send processing by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalOutEncryptFails{failure}/sdeviceOutbound encryptions which ended in failure by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalOutEncrypts{encryption}/sdeviceOutbound encryptions performed by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalOutOctetsBy/sdeviceData sent by IPsec Phase-2 Tunnels
snmp.device_prof_nec_pipSecGlobalOutPkts{packet}/sdevicePackets sent by IPsec Phase-2 Tunnels

System / CPU

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpu_usage%deviceThe current CPU utilization

System / Memory

Metric (chart context)UnitScopeDescription
snmp.device_prof_memory_usage%deviceMemory usage percentage

System / Uptime

Metric (chart context)UnitScopeDescription
snmp.device_prof_systemUptimesdeviceTime since the system was last rebooted or powered on.