Skip to main content

Nvidia Cumulus Linux Switch

Plugin: go.d.plugin Module: snmp

Overview

Monitor Nvidia Cumulus Linux Switch (switch) with Netdata over SNMP. Netdata recognizes the device automatically by its sysObjectID (recognized across 1 device identifiers) and collects the metrics this profile declares — on top of the generic SNMP baseline — with no manual OID configuration.

Netdata's SNMP collector matches the device to the nvidia-cumulus-linux-switch.yaml profile via sysObjectID/sysDescr, then polls the OIDs it declares.

This integration is supported on all platforms.

This integration supports multiple instances configured side-by-side.

Default Behavior

Auto-Detection

Auto-detected as Nvidia Cumulus Linux Switch via sysObjectID/sysDescr.

Limits

The default configuration for this integration does not impose any limits.

Performance Impact

The default configuration for this integration is not expected to impose a significant performance impact on the system.

Setup

You can configure the snmp collector in two ways:

MethodBest forHow to
UIFast setup without editing filesGo to Nodes → Configure this node → Collectors → Jobs, search for snmp, then click + to add a job.
FileIf you prefer configuring via file, or need to automate deployments (e.g., with Ansible)Edit go.d/snmp.conf and add a job.
important

UI configuration requires paid Netdata Cloud plan.

Prerequisites

SNMP access

SNMP must be enabled on the device and reachable from the Netdata Agent acting as the site's SNMP hub.

Configuration

Options

Configure the SNMP collector with the device hostname and SNMP credentials. See the SNMP collector reference for all options.

via UI

Configure the snmp collector from the Netdata web interface:

  1. Go to Nodes.
  2. Select the node where you want the snmp data-collection job to run and click the (Configure this node). That node will run the data collection.
  3. The Collectors → Jobs view opens by default.
  4. In the Search box, type snmp (or scroll the list) to locate the snmp collector.
  5. Click the + next to the snmp collector to add a new job.
  6. Fill in the job fields, then click Test to verify the configuration and Submit to save.
    • Test runs the job with the provided settings and shows whether data can be collected.
    • If it fails, an error message appears with details (for example, connection refused, timeout, or command execution errors), so you can adjust and retest.

via File

The configuration file name for this integration is go.d/snmp.conf.

The file format is YAML. Generally, the structure is:

update_every: 1
autodetection_retry: 0
jobs:
- name: some_name1
- name: some_name2

You can edit the configuration file using the edit-config script from the Netdata config directory.

cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/snmp.conf
Examples

There are no configuration examples.

Alerts

There are no alerts configured by default for this integration.

Metrics

On top of the generic SNMP baseline (the Generic SNMP Device integration — interfaces, system, IP/TCP/UDP, host resources), this Nvidia Cumulus Linux Switch profile adds the metrics below. Each is collected only where the device exposes the matching OID — inclusion means the profile requests it; availability depends on the device model and software.

101 metrics in 12 groups; each row is a chart context usable in alerts.

GroupMetrics
Hardware / PoE4
Hardware / Sensor2
Network / ACL16
Network / Interface35
Network / L22
Network / Routing8
System / Activity2
System / CPU3
System / Disk15
System / Memory11
System / Uptime1
Uncategorized2

Hardware / PoE

Metric (chart context)UnitScopeDescription
snmp.device_prof_cumulus_poeLastUpdateTimesdeviceThe system uptime timestamp when the objects in this MIB were last updated
snmp.device_prof_cumulus_poeTotalAvailablePowermWdeviceThe total UNUSED and available power for the system in the common pool for new devices
snmp.device_prof_cumulus_poeTotalSystemPowermWdeviceThe total power available to the system
snmp.device_prof_cumulus_poeTotalUsedPowermWdeviceThe total power USED by ports in the system

Hardware / Sensor

Metric (chart context)UnitScopeDescription
snmp.device_prof_entPhySensorOperStatus{status}per sensor_index, rm:sensor_type, rm:sensor_scale, rm:sensor_precisionOperational status of the sensor
snmp.device_prof_entPhySensorValue1per sensor_index, rm:sensor_type, rm:sensor_scale, rm:sensor_precisionMost recent measurement obtained by the agent for this sensor

Network / ACL

Metric (chart context)UnitScopeDescription
snmp.device_prof_cumulus_egressAclCurrentCounters{counter}deviceThe current number of Egress counters in the Network Access Control List table
snmp.device_prof_cumulus_egressAclCurrentEntries{entry}deviceThe current number of Egress entries in the Network Access Control List table
snmp.device_prof_cumulus_egressAclCurrentMeters{meter}deviceThe current number of Egress meters in the Network Access Control List table
snmp.device_prof_cumulus_egressAclCurrentSlices{slice}deviceThe current number of Egress slices in the Network Access Control List table
snmp.device_prof_cumulus_egressAclMaxCounters{counter}deviceThe maximum possible Egress counters in the Network Access Control table
snmp.device_prof_cumulus_egressAclMaxEntries{entry}deviceThe maximum possible Egress entries in the Network Access Control table
snmp.device_prof_cumulus_egressAclMaxMeters{meter}deviceThe maximum possible Egress meters in the Network Access Control table
snmp.device_prof_cumulus_egressAclMaxSlices{slice}deviceThe maximum possible Egress slices in the Network Access Control table
snmp.device_prof_cumulus_ingressAclCurrentCounters{counter}deviceThe current number of Ingress counters in the Network Access Control List table
snmp.device_prof_cumulus_ingressAclCurrentEntries{entry}deviceThe current number of Ingress entries in the Network Access Control List table
snmp.device_prof_cumulus_ingressAclCurrentMeters{meter}deviceThe current number of Ingress meters in the Network Access Control List table
snmp.device_prof_cumulus_ingressAclCurrentSlices{slice}deviceThe current number of Ingress slices in the Network Access Control List table
snmp.device_prof_cumulus_ingressAclMaxCounters{counter}deviceThe maximum possible Ingress counters in the Network Access Control table
snmp.device_prof_cumulus_ingressAclMaxEntries{entry}deviceThe maximum possible Ingress entries in the Network Access Control table
snmp.device_prof_cumulus_ingressAclMaxMeters{meter}deviceThe maximum possible Ingress meters in the Network Access Control table
snmp.device_prof_cumulus_ingressAclMaxSlices{slice}deviceThe maximum possible Ingress slices in the Network Access Control table

Network / Interface

Metric (chart context)UnitScopeDescription
snmp.device_prof_cumulus_clBufferOverflowDiscards{packet}/sper cumulus_cl_port_index, cumulus_cl_port_nameNumber of inbound packets discarded due to ingress buffer overflow.
snmp.device_prof_cumulus_clEgressNonQDiscards{packet}/sper cumulus_cl_port_index, cumulus_cl_port_nameTotal number of packets discarded on egress due to reasons reasons other than queue overflow.
snmp.device_prof_cumulus_clEgressQOverflowDiscards{packet}/sper cumulus_cl_port_index, cumulus_cl_port_nameNumber of packets discarded due to egress queue overflow.
snmp.device_prof_cumulus_clIntInBcastPkts{packet}/sper cumulus_cl_int_index, cumulus_cl_int_port_nameThe number of input broadcast packets on the interface
snmp.device_prof_cumulus_clIntInMcastPkts{packet}/sper cumulus_cl_int_index, cumulus_cl_int_port_nameThe number of input multicast packets on the interface
snmp.device_prof_cumulus_clIntInOctetsbit/sper cumulus_cl_int_index, cumulus_cl_int_port_nameThe number of input octets on the interface
snmp.device_prof_cumulus_clIntInPausePkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet flow control pause packets received on the interface
snmp.device_prof_cumulus_clIntInPfc0Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 0 packets received on the interface
snmp.device_prof_cumulus_clIntInPfc1Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 1 packets received on the interface
snmp.device_prof_cumulus_clIntInPfc2Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 2 packets received on the interface
snmp.device_prof_cumulus_clIntInPfc3Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 3 packets received on the interface
snmp.device_prof_cumulus_clIntInPfc4Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 4 packets received on the interface
snmp.device_prof_cumulus_clIntInPfc5Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 5 packets received on the interface
snmp.device_prof_cumulus_clIntInPfc6Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 6 packets received on the interface
snmp.device_prof_cumulus_clIntInPfc7Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 7 packets received on the interface
snmp.device_prof_cumulus_clIntInUcastPkts{packet}/sper cumulus_cl_int_index, cumulus_cl_int_port_nameThe number of input unicast packets on the interface
snmp.device_prof_cumulus_clIntOutBcastPkts{packet}/sper cumulus_cl_int_index, cumulus_cl_int_port_nameThe number of output broadcast packets on the interface
snmp.device_prof_cumulus_clIntOutMcastPkts{packet}/sper cumulus_cl_int_index, cumulus_cl_int_port_nameThe number of output multicast packets on the interface
snmp.device_prof_cumulus_clIntOutOctetsbit/sper cumulus_cl_int_index, cumulus_cl_int_port_nameThe number of output octets on the interface
snmp.device_prof_cumulus_clIntOutPausePkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet flow control pause packets transmitted on the interface
snmp.device_prof_cumulus_clIntOutPfc0Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 0 packets transmitted on the interface
snmp.device_prof_cumulus_clIntOutPfc1Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 1 packets transmitted on the interface
snmp.device_prof_cumulus_clIntOutPfc2Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 2 packets transmitted on the interface
snmp.device_prof_cumulus_clIntOutPfc3Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 3 packets transmitted on the interface
snmp.device_prof_cumulus_clIntOutPfc4Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 4 packets transmitted on the interface
snmp.device_prof_cumulus_clIntOutPfc5Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 5 packets transmitted on the interface
snmp.device_prof_cumulus_clIntOutPfc6Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 6 packets transmitted on the interface
snmp.device_prof_cumulus_clIntOutPfc7Pkt{packet}/sper cumulus_cl_int_pfc_index, cumulus_cl_int_pfc_port_nameThe number of ethernet priority flow control traffic class 7 packets transmitted on the interface
snmp.device_prof_cumulus_clIntOutUcastPkts{packet}/sper cumulus_cl_int_index, cumulus_cl_int_port_nameThe number of output unicast packets on the interface
snmp.device_prof_cumulus_clL3AclDiscards{packet}/sper cumulus_cl_port_index, cumulus_cl_port_nameNumber of inbound IPv4 packets discarded due to ingress ACL table.
snmp.device_prof_cumulus_clL3v4InDiscards{packet}/sper cumulus_cl_port_index, cumulus_cl_port_nameNumber of inbound IPv4 packets discarded by the routing engine.
snmp.device_prof_ifAdminStatus{status}per interface, interfaceCurrent administrative state of the interface
snmp.device_prof_ifHighSpeedbit/sper interface, interfaceEstimate of the interface's current bandwidth
snmp.device_prof_ifNumber{interface}deviceNumber of network interfaces regardless of their current state present on this system
snmp.device_prof_ifOperStatus{status}per interface, interfaceCurrent operational state of the interface

Network / L2

Metric (chart context)UnitScopeDescription
snmp.device_prof_cumulus_l2MacTableCurrentEntries{entry}deviceThe number of L2 Mac table entries currently in use
snmp.device_prof_cumulus_l2MacTableMaxEntries{entry}deviceThe maximum possible entries in the L2 Mac table

Network / Routing

Metric (chart context)UnitScopeDescription
snmp.device_prof_cumulus_l3EcmpNextHopTableCurrentEntries{entry}deviceThe number of ECMP Next Hop table entries currently in use
snmp.device_prof_cumulus_l3EcmpNextHopTableMaxEntries{entry}deviceThe maximum possible entries in the ECMP Next Hop table
snmp.device_prof_cumulus_l3HostTableCurrentEntries{entry}deviceThe number of L3 Host table entries currently in use
snmp.device_prof_cumulus_l3HostTableMaxEntries{entry}deviceThe maximum possible entries in the L3 Host table
snmp.device_prof_cumulus_l3NextHopTableCurrentEntries{entry}deviceThe number of L3 Next Hop table entries currently in use
snmp.device_prof_cumulus_l3NextHopTableMaxEntries{entry}deviceThe maximum possible entries in the L3 Next Hop table
snmp.device_prof_cumulus_l3RoutingTableCurrentEntries{entry}deviceThe number of L3 Routing table entries currently in use
snmp.device_prof_cumulus_l3RoutingTableMaxEntries{entry}deviceThe maximum possible entries in the L3 Routing table

System / Activity

Metric (chart context)UnitScopeDescription
snmp.device_prof_hrSystemNumUsers{session}deviceThe number of user sessions for which this host is storing state information. A session is a collection of processes requiring a s…
snmp.device_prof_hrSystemProcesses{process}deviceThe number of process contexts currently loaded or running on this system.

System / CPU

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpu_usage%per cpu_indexThe current CPU utilization
snmp.device_prof_ucd_ssRawContexts{switch}/sdeviceNumber of context switches
snmp.device_prof_ucd_ssRawInterrupts{interrupt}/sdeviceNumber of interrupts processed

System / Disk

Metric (chart context)UnitScopeDescription
snmp.device_prof_ucd_diskIOLA1%per ucd_disk_io_deviceThe 1 minute average load of disk (%)
snmp.device_prof_ucd_diskIOLA15%per ucd_disk_io_deviceThe 15 minute average load of disk (%)
snmp.device_prof_ucd_diskIOLA5%per ucd_disk_io_deviceThe 5 minute average load of disk (%)
snmp.device_prof_ucd_diskIONReadXBy/sper ucd_disk_io_deviceThe number of bytes read from this device since boot
snmp.device_prof_ucd_diskIONWrittenXBy/sper ucd_disk_io_deviceThe number of bytes written to this device since boot
snmp.device_prof_ucd_diskIOReads{read}/sper ucd_disk_io_deviceThe number of read accesses from this device since boot
snmp.device_prof_ucd_diskIOWrites{write}/sper ucd_disk_io_deviceThe number of write accesses to this device since boot
snmp.device_prof_ucd_dskAvailByper ucd_dsk_path, ucd_dsk_deviceAvailable space on the disk
snmp.device_prof_ucd_dskErrorFlag{status}per ucd_dsk_path, ucd_dsk_deviceFlag signaling that the disk or partition is under the minimum required space configured for it
snmp.device_prof_ucd_dskPercent%per ucd_dsk_path, ucd_dsk_devicePercentage of space used on disk
snmp.device_prof_ucd_dskPercentNode%per ucd_dsk_path, ucd_dsk_devicePercentage of inodes used on disk
snmp.device_prof_ucd_dskTotalByper ucd_dsk_path, ucd_dsk_deviceTotal size of the disk/partition
snmp.device_prof_ucd_dskUsedByper ucd_dsk_path, ucd_dsk_deviceUsed space on the disk
snmp.device_prof_ucd_ssIORawReceivedBy/sdeviceAmount of data read from disk or other block device
snmp.device_prof_ucd_ssIORawSentBy/sdeviceAmount of data written to disk or other block device

System / Memory

Metric (chart context)UnitScopeDescription
snmp.device_prof_memory_freeBydeviceThe amount of real/physical memory currently unused or available
snmp.device_prof_ucd_memAvailSwapBydeviceThe amount of swap space currently unused or available
snmp.device_prof_ucd_memBufferBydeviceThe total amount of real or virtual memory currently allocated for use as memory buffers
snmp.device_prof_ucd_memCachedBydeviceThe total amount of real or virtual memory currently allocated for use as cached memory
snmp.device_prof_ucd_memMinimumSwapBydeviceThe minimum amount of swap space expected to be kept free or available during normal operation of this host
snmp.device_prof_ucd_memSharedBydeviceThe total amount of real or virtual memory currently allocated for use as shared memory
snmp.device_prof_ucd_memTotalFreeBydeviceThe total amount of memory free or available for use on this host
snmp.device_prof_ucd_memTotalSwapBydeviceThe total amount of swap space configured for this host
snmp.device_prof_ucd_memoryTotalBydeviceThe total amount of real/physical memory installed on this host
snmp.device_prof_ucd_ssRawSwapInBy/sdeviceAmount of memory swapped in from disk
snmp.device_prof_ucd_ssRawSwapOutBy/sdeviceAmount of memory swapped out to disk

System / Uptime

Metric (chart context)UnitScopeDescription
snmp.device_prof_systemUptimesdeviceTime since the system was last rebooted or powered on.

Uncategorized

Metric (chart context)UnitScopeDescription
snmp.device_prof_hrStorageSizeByper storage_index, rm:storage_type, rm:storage_alloc_unit
snmp.device_prof_hrStorageUsedByper storage_index, rm:storage_type, rm:storage_alloc_unit

Do you have any feedback for this page? If so, you can open a new issue on our netdata/learn repository.