Servertech Pdu3

Plugin: go.d.plugin Module: snmp

Overview

Monitor Servertech Pdu3 (pdu) with Netdata over SNMP. Netdata recognizes the device automatically by its sysObjectID (recognized across 1 device identifiers) and collects the metrics this profile declares — on top of the generic SNMP baseline — with no manual OID configuration.

Netdata's SNMP collector matches the device to the servertech-pdu3.yaml profile via sysObjectID/sysDescr, then polls the OIDs it declares.

This integration is supported on all platforms.

This integration supports multiple instances configured side-by-side.

Default Behavior

Auto-Detection

Auto-detected as Servertech Pdu3 via sysObjectID/sysDescr.

Limits

The default configuration for this integration does not impose any limits.

Performance Impact

The default configuration for this integration is not expected to impose a significant performance impact on the system.

Setup

You can configure the snmp collector in two ways:

MethodBest forHow to
UIFast setup without editing filesGo to Nodes → Configure this node → Collectors → Jobs, search for snmp, then click + to add a job.
FileIf you prefer configuring via file, or need to automate deployments (e.g., with Ansible)Edit go.d/snmp.conf and add a job.
important

UI configuration requires paid Netdata Cloud plan.

Prerequisites

SNMP access

SNMP must be enabled on the device and reachable from the Netdata Agent acting as the site's SNMP hub.

Configuration

Options

Configure the SNMP collector with the device hostname and SNMP credentials. See the SNMP collector reference for all options.

via UI

Configure the snmp collector from the Netdata web interface:

  1. Go to Nodes.
  2. Select the node where you want the snmp data-collection job to run and click the (Configure this node). That node will run the data collection.
  3. The Collectors → Jobs view opens by default.
  4. In the Search box, type snmp (or scroll the list) to locate the snmp collector.
  5. Click the + next to the snmp collector to add a new job.
  6. Fill in the job fields, then click Test to verify the configuration and Submit to save.
    • Test runs the job with the provided settings and shows whether data can be collected.
    • If it fails, an error message appears with details (for example, connection refused, timeout, or command execution errors), so you can adjust and retest.

via File

The configuration file name for this integration is go.d/snmp.conf.

The file format is YAML. Generally, the structure is:

update_every: 1
autodetection_retry: 0
jobs:
- name: some_name1
- name: some_name2

You can edit the configuration file using the edit-config script from the Netdata config directory.

cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/snmp.conf
Examples

There are no configuration examples.

Alerts

There are no alerts configured by default for this integration.

Metrics

On top of the generic SNMP baseline (the Generic SNMP Device integration — interfaces, system, IP/TCP/UDP, host resources), this Servertech Pdu3 profile adds the metrics below. Each is collected only where the device exposes the matching OID — inclusion means the profile requests it; availability depends on the device model and software.

33 metrics in 9 groups; each row is a chart context usable in alerts.

GroupMetrics
Hardware / Infeed2
Hardware / Outlet3
Hardware / Sensor6
Hardware / Tower1
PowerFlow / Infeed10
PowerFlow / System1
PowerFlow / Tower8
System / Configuration1
System / Uptime1

Hardware / Infeed

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_infeedLoadStatus{status}per servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed load status
snmp.device_prof_servertech_sentry3_infeedStatus{status}per servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed operational status

Hardware / Outlet

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_outletControlState{status}per servertech_sentry3_outlet_id, servertech_sentry3_outlet_nameOutlet control state
snmp.device_prof_servertech_sentry3_outletStatus{status}per servertech_sentry3_outlet_id, servertech_sentry3_outlet_nameOutlet operational status
snmp.device_prof_servertech_sentry3_outletWakeupState{status}per servertech_sentry3_outlet_id, servertech_sentry3_outlet_nameOutlet wakeup state configuration

Hardware / Sensor

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_envMonStatus{status}per servertech_sentry3_env_mon_id, servertech_sentry3_env_mon_nameEnvironmental monitor status
snmp.device_prof_servertech_sentry3_tempHumidSensorHumidStatus{status}per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameHumidity sensor status
snmp.device_prof_servertech_sentry3_tempHumidSensorHumidValue%per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameHumidity value from sensor
snmp.device_prof_servertech_sentry3_tempHumidSensorStatus{status}per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameTemperature/humidity sensor communication status
snmp.device_prof_servertech_sentry3_tempHumidSensorTempStatus{status}per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameTemperature sensor status
snmp.device_prof_servertech_sentry3_tempHumidSensorTempValueCelper servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameTemperature value from sensor

Hardware / Tower

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_towerStatus{status}per servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower operational status

PowerFlow / Infeed

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_infeedCapacityVAper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed capacity
snmp.device_prof_servertech_sentry3_infeedCapacityUsedVAper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameUsed infeed capacity
snmp.device_prof_servertech_sentry3_infeedEnergyWhper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed energy consumption
snmp.device_prof_servertech_sentry3_infeedLoadValueWper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed load value
snmp.device_prof_servertech_sentry3_infeedOutletCount{outlet}per servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameNumber of outlets on infeed
snmp.device_prof_servertech_sentry3_infeedPhaseCurrentAper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed phase current
snmp.device_prof_servertech_sentry3_infeedPhaseVoltageVper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed phase voltage
snmp.device_prof_servertech_sentry3_infeedPowerWper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed power
snmp.device_prof_servertech_sentry3_infeedReactance{status}per servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed reactance type
snmp.device_prof_servertech_sentry3_infeedVoltageVper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed voltage

PowerFlow / System

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_systemTotalPowerWdeviceTotal power consumption of the system

PowerFlow / Tower

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_towerActivePowerWper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower active power
snmp.device_prof_servertech_sentry3_towerApparentPowerVAper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower apparent power
snmp.device_prof_servertech_sentry3_towerEnergyWhper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower energy consumption
snmp.device_prof_servertech_sentry3_towerInfeedCount{infeed}per servertech_sentry3_tower_id, servertech_sentry3_tower_nameNumber of tower infeeds
snmp.device_prof_servertech_sentry3_towerLineFrequencyHzper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower line frequency
snmp.device_prof_servertech_sentry3_towerPowerFactor%per servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower power factor
snmp.device_prof_servertech_sentry3_towerVACapacityVAper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower VA capacity
snmp.device_prof_servertech_sentry3_towerVACapacityUsedVAper servertech_sentry3_tower_id, servertech_sentry3_tower_nameUsed tower VA capacity

System / Configuration

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_systemConfigModifiedCount{modification}deviceCount of system configuration modifications

System / Uptime

Metric (chart context)UnitScopeDescription
snmp.device_prof_systemUptimesdeviceTime since the system was last rebooted or powered on.