Tripplite PDU

Plugin: go.d.plugin Module: snmp

Overview

Monitor Tripplite PDU (pdu) with Netdata over SNMP. Netdata recognizes the device automatically by its sysObjectID (recognized across 1 device identifiers) and collects the metrics this profile declares — on top of the generic SNMP baseline — with no manual OID configuration.

Netdata's SNMP collector matches the device to the tripplite-pdu.yaml profile via sysObjectID/sysDescr, then polls the OIDs it declares.

This integration is supported on all platforms.

This integration supports multiple instances configured side-by-side.

Default Behavior

Auto-Detection

Auto-detected as Tripplite PDU via sysObjectID/sysDescr.

Limits

The default configuration for this integration does not impose any limits.

Performance Impact

The default configuration for this integration is not expected to impose a significant performance impact on the system.

Setup

You can configure the snmp collector in two ways:

MethodBest forHow to
UIFast setup without editing filesGo to Nodes → Configure this node → Collectors → Jobs, search for snmp, then click + to add a job.
FileIf you prefer configuring via file, or need to automate deployments (e.g., with Ansible)Edit go.d/snmp.conf and add a job.
important

UI configuration requires paid Netdata Cloud plan.

Prerequisites

SNMP access

SNMP must be enabled on the device and reachable from the Netdata Agent acting as the site's SNMP hub.

Configuration

Options

Configure the SNMP collector with the device hostname and SNMP credentials. See the SNMP collector reference for all options.

via UI

Configure the snmp collector from the Netdata web interface:

  1. Go to Nodes.
  2. Select the node where you want the snmp data-collection job to run and click the (Configure this node). That node will run the data collection.
  3. The Collectors → Jobs view opens by default.
  4. In the Search box, type snmp (or scroll the list) to locate the snmp collector.
  5. Click the + next to the snmp collector to add a new job.
  6. Fill in the job fields, then click Test to verify the configuration and Submit to save.
    • Test runs the job with the provided settings and shows whether data can be collected.
    • If it fails, an error message appears with details (for example, connection refused, timeout, or command execution errors), so you can adjust and retest.

via File

The configuration file name for this integration is go.d/snmp.conf.

The file format is YAML. Generally, the structure is:

update_every: 1
autodetection_retry: 0
jobs:
- name: some_name1
- name: some_name2

You can edit the configuration file using the edit-config script from the Netdata config directory.

cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/snmp.conf
Examples

There are no configuration examples.

Alerts

There are no alerts configured by default for this integration.

Metrics

On top of the generic SNMP baseline (the Generic SNMP Device integration — interfaces, system, IP/TCP/UDP, host resources), this Tripplite PDU profile adds the metrics below. Each is collected only where the device exposes the matching OID — inclusion means the profile requests it; availability depends on the device model and software.

19 metrics in 10 groups; each row is a chart context usable in alerts.

GroupMetrics
Environment / Temperature2
Hardware / Breaker1
Hardware / Device1
Hardware / Outlet1
Hardware / Output1
PowerFlow / Outlet3
PowerFlow / Output5
PowerFlow / Phase1
System / Alarm3
System / Uptime1

Environment / Temperature

Metric (chart context)UnitScopeDescription
snmp.device_prof_tlpPduDeviceTemperatureCCelper tlp_device_indexThe ambient temperature at or near the PDU casing.
snmp.device_prof_tlpPduDeviceTemperatureFdegFper tlp_device_indexThe ambient temperature at or near the PDU casing.

Hardware / Breaker

Metric (chart context)UnitScopeDescription
snmp.device_prof_tlpPduBreakerStatus{status}per tlp_device_index, tlp_pdu_breaker_index, tlp_pdu_breaker_statusThe current state of the bank breaker

Hardware / Device

Metric (chart context)UnitScopeDescription
snmp.device_prof_tlpDeviceStatus{status}per tlp_device_indexThe currently most critical alarm status for the device

Hardware / Outlet

Metric (chart context)UnitScopeDescription
snmp.device_prof_tlpPduOutletState{status}per tlp_pdu_outlet_nameThe current state of the outlet.

Hardware / Output

Metric (chart context)UnitScopeDescription
snmp.device_prof_tlpPduDeviceMainLoadState{status}per tlp_device_indexThe current state of the main output of the device

PowerFlow / Outlet

Metric (chart context)UnitScopeDescription
snmp.device_prof_tlpPduOutletCurrentmAper tlp_pdu_outlet_nameThe present output current, in hundreths of amps, of a given outlet.
snmp.device_prof_tlpPduOutletPowerWper tlp_pdu_outlet_nameThe output power of a given outlet.
snmp.device_prof_tlpPduOutletVoltageVper tlp_pdu_outlet_nameThe magnitude of the present output voltage for a given outlet.

PowerFlow / Output

Metric (chart context)UnitScopeDescription
snmp.device_prof_tlpPduDeviceOutputPowerTotalWper tlp_device_indexThe AC output total power for all circuits.
snmp.device_prof_tlpPduOutputCurrentmAper tlp_device_index, tlp_pdu_output_index, tlp_pdu_output_phase, tlp_pdu_output_phase_typeThe output current, in hundreths of amps, for a given phase.
snmp.device_prof_tlpPduOutputFrequencyHzper tlp_device_index, tlp_pdu_output_index, tlp_pdu_output_phase, tlp_pdu_output_phase_typeThe present output frequency.
snmp.device_prof_tlpPduOutputSource{status}per tlp_device_index, tlp_pdu_output_index, tlp_pdu_output_phase, tlp_pdu_output_phase_typeThe present source of output power.
snmp.device_prof_tlpPduOutputVoltageVper tlp_device_index, tlp_pdu_output_index, tlp_pdu_output_phase, tlp_pdu_output_phase_typeThe magnitude of the present output voltage for a given output line.

PowerFlow / Phase

Metric (chart context)UnitScopeDescription
snmp.device_prof_tlpPduDevicePhaseImbalance%per tlp_device_indexThe percentage of imbalance of the three phases.

System / Alarm

Metric (chart context)UnitScopeDescription
snmp.device_prof_tlpAlarmAcknowledged{status}per tlp_alarm_indexDenotes whether the alarm condition has been acknowledged
snmp.device_prof_tlpAlarmState{status}per tlp_alarm_indexThe current state of this alarm condition
snmp.device_prof_tlpAlarmsPresent{alarm}deviceThe present number of active alarm conditions.

System / Uptime

Metric (chart context)UnitScopeDescription
snmp.device_prof_systemUptimesdeviceTime since the system was last rebooted or powered on.